ProductName: Patient Monitor KGW-2000
ProductIntroduce:

Characteristics

l            20 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table

l            Efficient resistance to interference of defibrillator and electrosurgical cautery

l            SPO2 can testing for 0.1% Weak

l            RA-LL impedance Respiration

l            Trend Coexist Display

l            OxyCRG DyNamic View Display

l            Bed to Bed view Display

l            Networking capacity and nurse_calling system

l            Options of printing, IBP, VGA and EtCO2.

l            UP to 4 hours working capacity of built_in rechargeable battery.

l            12.1"high resolution color TFT LCD display.

l            Large volume of tabular and graphic trends information storage and easy to recall.

l            Anti-ESU, anti- defibrillator

l            6 Standard parameters:ECG,RESP,NIBP,SPO2,1_TEMP,PR/HR.

l            Capture dynamic waveforms.

Size and Weight

Size: 290mmX333mmX157mm (for 12.1)

Weight: 4.8kg (for 12.1)

Size: 290mmX330mmX140mm (for 10.4)

Weight: 4.8kg(for 10.4)

Power supply

Power Voltage: 100~250 (V)AC, 50/60 (Hz)

Power Input: 110VA, FUSE T 3.0A

Display

Size: 10.4 or 12.1

Type: Color TFT-LCD

Battery

Type: Rechargeable Lead acid cell, 12V/2.0AH

Charge time: ≤4 hours

Environment

Working temperature: 0 ~ 40 (°C)

Transport and storage temperature: -20 ~ 60 (°C)

Working humidity: <= 85 %

Transport and storage humidity: <= 93 %

Working altitude: -500 to 4,600m (-1,600 to 15,000ft)

Transport and storage altitude: -500 to 13,100m (-1,600 to 43,000ft)

ECG

Lead Mode: 5 Leads (     R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 channel

Lead mode: 3 Leads ( R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 channel

Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto

HR and Alarm         :      

Range   

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm,which great

Resolution: 1 bpm

Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR:

Monitor: > 105 dB

Operation: > 105 dB

Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: < 10 uA

Baseline Recovery: < 3 S  After Defi.

ECG Signal Range: ±8 m V ( Vp-p )        

Bandwidth:    

Surgery: 1 ~ 15 Hz

Monitor: 0.5 ~ 35 Hz

Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p)

Accuracy:±5% 

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting:     

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

Respiration

Method: Impedance between R-F(RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range:        0.3~5.0Ω

Base line Impedance Range: 0 – 2.5  KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate:

Measuring and Alarm Range

Adult: 0 ~ 120 rpm

Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy          : ±2 rpm

Apean Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range                     

Adult Mode:

SYS: 40 ~ 270 mmHg

DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

Pediatric Mode:

SYS: 40 ~ 200 mmHg

DIA: 10 ~ 150 mmHg

MEAN: 20 ~ 165 mmHg

Neonatal Mode:

SYS: 40 ~ 135 mmHg

DIA: 10 ~ 100 mmHg

MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

Adult Mode: 297±3 mmHg

Pediatric Mode: 240±3 mmHg

Neonatal Mode: 147±3 mmHg

SpO2

 

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %, 0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate:

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy: ±2bpm

Temperature

 

Channel: 1

Measuring and Alarm Range: 0 ~ 50 °C

Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant: <10 Sec.

IBP (For Option)

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

ART: 0 ~ 300 mmHg

PA: -6 ~ 120 mmHg

CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

P1/P2: -10 ~ 300 mmHg                                              

Press Sensor:

Sensitivity: 5 uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great

Actualization interval: about 1 Sec.

Standard Accessories

5-lead ECG cable: 1pc

NIBP Adult Cuff: 1pc

NIBP Extension Tube: 1pc

Adult SPO2 Sensor: 1 pc

Body Surface TEMP Probe: 1 pc

Rechargeable sealed lead-acid battery 12V: 1 pc

Charger: 1pc

Optional Accessories

Printer

CO2

IBP

NIBP Child Cuff

 

 