ProductIntroduce: Characteristics
l 20 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table
l Efficient resistance to interference of defibrillator and electrosurgical cautery
l SPO2 can testing for 0.1% Weak
l RA-LL impedance Respiration
l Trend Coexist Display
l OxyCRG DyNamic View Display
l Bed to Bed view Display
l Networking capacity and nurse_calling system
l Options of printing, IBP, VGA and EtCO2.
l UP to 4 hours working capacity of built_in rechargeable battery.
l 12.1"high resolution color TFT LCD display.
l Large volume of tabular and graphic trends information storage and easy to recall.
l Anti-ESU, anti- defibrillator
l 6 Standard parameters:ECG,RESP,NIBP,SPO2,1_TEMP,PR/HR.
l Capture dynamic waveforms.
Size and Weight
Size: 290mmX333mmX157mm (for 12.1)
Weight: 4.8kg (for 12.1)
Size: 290mmX330mmX140mm (for 10.4)
Weight: 4.8kg(for 10.4)
Power supply
Power Voltage: 100~250 (V)AC, 50/60 (Hz)
Power Input: 110VA, FUSE T 3.0A
Display
Size: 10.4 or 12.1″
Type: Color TFT-LCD
Battery
Type: Rechargeable Lead acid cell, 12V/2.0AH
Charge time: ≤4 hours
Environment
Working temperature: 0 ~ 40 (°C)
Transport and storage temperature: -20 ~ 60 (°C)
Working humidity: <= 85 %
Transport and storage humidity: <= 93 %
Working altitude: -500 to 4,600m (-1,600 to 15,000ft)
Transport and storage altitude: -500 to 13,100m (-1,600 to 43,000ft)
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 channel
Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1 channel
Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto
HR and Alarm :
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm,which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR:
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 S After Defi.
ECG Signal Range: ±8 m V ( Vp-p )
Bandwidth:
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p)
Accuracy:±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting:
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
Respiration
Method: Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate:
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy : ±2 rpm
Apean Alarm: 10 ~ 40 S
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode:
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode:
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode:
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 110 mmHg
Resolution Pressure: 1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg
SpO2
Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %, 0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate:
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy: ±2bpm
Temperature
Channel: 1
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant: <10 Sec.
IBP (For Option)
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor:
Sensitivity: 5 uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec.
Standard Accessories
5-lead ECG cable: 1pc
NIBP Adult Cuff: 1pc
NIBP Extension Tube: 1pc
Adult SPO2 Sensor: 1 pc
Body Surface TEMP Probe: 1 pc
Rechargeable sealed lead-acid battery 12V: 1 pc
Charger: 1pc
Optional Accessories
Printer
CO2
IBP
NIBP Child Cuff
|