ProductIntroduce£º Characteristics
l 7’’ TFT LCD display, high resolution
l Parameter detection: 5 Lead ECG, RESP, SPO2, NIBP, TEMP
l Built-in rechargeable battery
l User-Friendly operational window
l 60s full disclosure of ECG playback
l 48 hours tabular and graphic trends & data storage
l Digital SPO2, high capacity against interference of ESU, motion & low infusion
l Isolated against defibrillation effect
l Wireless or wire communicable with central station system
Size and Weight
Size: 256mm×209mm×185mm
Weight: 4.0kg
Power supply
Power Voltage: AC 100-240V 50/60Hz
Power Input: ≤70VA
Display
Size: 7″
Type: Color TFT-LCD
Battery
Type: Rechargeable Lead acid cell, 12V/3.2AH
Charge time: ≤10 hours
Working time: ≥60min when using normally
Environment
Ambient Temperature: Working temperature: 0~+40ºC; If use EtCO2 of IRMA, working temperature: +10~+40ºC; If use O2 sensor of IRMA, working temperature: +10~+35ºC; Transportation and storage temperature: –20~+55ºC
Relative humidity: Working ≤85%, Transportation and storage ≤93%
Atmospheric pressure: Working 860~1060 hPa, Transportation and storage 500~1060 hPa
ECG
Leads: I, II, III, aVR, aVL, aVF, Cx
Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
Input impedance: ≥5MΩ (d.c.~60Hz)
Common Mode Rejection Ratio: ≥85dB(diagnostic mode), ≥105dB(monitoring & surgica mode)
Bandwith: 0.5-40Hz (monitoring mode), 0.05-120Hz(diagnostic mode), 1-25Hz (surgical mode)
Protection: Segregation breakdown voltage 4000VAC, 50/60Hz
Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
Indication of Detachment of electrodes: Available
Playback of Cardiogram: Available
Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range: 10-300BPM
Accuracy: ±1BPM
RESP
Method: Impedance Measurement
Measuring Range: 0-120bpm
Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
Apnea alarm: Available
TEMP
Channel: 2 channels
Range: 0~50¡æ
Unit: Celsius, Fahrenheit
Resolution: 1mmHg
Accuracy: ±0.1¡æ (25¡æ~50¡æ)
SPO2 (Pulse Oximetry)
Range: 0-100%
Accuracy: ±2% (70%~100%); ±3%(35%~ 69%); Unspecified (0~34%)
Range & Accuracy of Pulse Rate: 25~250BPM ± 1BPM
NIBP
Method: Automatic oscillometric
Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
Measurement: Systolic pressure/diastolic pressure/mean
Range: Adult: 10-270mmHg
Pediatric: 10-235mmHg
Neonate: 10-135mmHg
Unit: mmHg / Kpa selectable
Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2, 4, 8,12 hours
600 groups of NIBP measuring data review
Printer (Option)
Method: Thermal dot array
Paper width: 50 mm (1.97 in)
Paper Speed: 12.5/25/50 (mm/sec)
Traces: Maximum 3 tracks
Alarm
Level: Low, medium and high
Indication: Auditory and visual
Setup: Default and custom
Silence: All alarms can be silenced
Volume: 45~85 dB measured at 1 meter
Standard Accessories
5-lead ECG cable: 1pc
ECG disposable electrode: 10pcs
NIBP reusable adult cuff with air hose & connector: 1 set
Digital adult reusable SPO2 sensor: 1 pc
Temp reusable skin probe: 1 pc
Rechargeable sealed lead-acid battery 12V: 1 pc
Power line: 1pc
Optional Accessories
Nellcor SPO2 with accessories kit
2-Temp
Thermal recorder (including 1 roll paper)
3-lead ECG cable
Trolley
Wall mount bracket
|