ProductIntroduce
Model
|
B-3000
|
B-2000
|
B-1000
|
B-800
|
Mattress to hood
|
450mm
|
450mm
|
450mm
|
410mm
|
Observation side of hood
|
Two incline
|
Two incline
|
Two incline
|
Two incline
|
Operate port
|
6(2 Iris ports)
|
6(2 Iris ports)
|
6(2 Iris ports)
|
4(2 Iris ports)
|
Tubing grommets
|
4
|
4
|
4
|
2
|
Front access panel
|
826*310mm
|
826*310mm
|
826*310mm
|
826*280mm
|
Mattress tray size
|
630*360mm
|
630*360mm
|
630*360mm
|
630*360mm
|
Power requirement
|
≤400VA
|
≤400VA
|
≤400VA
|
≤400VA
|
Temperature control mode
|
Air and skin servo control
|
Air and skin servo control
|
Air servo control
|
Air servo control
|
Air temperature control range
|
20-37
|
20-37
|
20-37
|
20-37
|
Temperature override mode to
|
20-39
|
20-39
|
20-39
|
None
|
Skin temp sensor accuracy
|
30-37
|
30-37
|
None
|
None
|
Temperature override mode to
|
30-38
|
30-38
|
None
|
None
|
Humidity display range
|
5-99%
|
None
|
None
|
None
|
Temperature fluctuation
|
≤0.5
|
≤0.5
|
≤0.5
|
≤0.5
|
Mattress temperature uniformity
|
≤0.8
|
≤0.8
|
≤0.8
|
≤0.8
|
Temperature rise time
|
≤30min
|
≤30min
|
≤30min
|
≤30min
|
Noise level within hood environment
|
≤55db
|
≤55db
|
≤55db
|
≤55db
|
Power failure alarm
|
Yes
|
Yes
|
Yes
|
Yes
|
Fan failure alarm
|
Yes
|
Yes
|
Yes
|
Yes
|
Sensor failure alarm
|
Yes
|
Yes
|
Yes
|
Yes
|
High air temperature alarm
|
1.5
|
1.5
|
1.5
|
1.5
|
Low air temperature alarm
|
2.5
|
2.5
|
2.5
|
2.5
|
High skin temperature alarm
|
1.0
|
1.0
|
None
|
None
|
Low skin temperature alarm
|
1.0
|
1.0
|
None
|
None
|
Over air temperature alarm
|
≤38
≤40
|
≤38
≤40
|
≤38
≤40
|
≤38
|
Over skin temperature alarm
|
≤38
≤39
|
≤38
≤39
|
None
|
None
|
System failure alarm
|
Yes
|
Yes
|
Yes
|
none
|
Alarm silence function
|
Yes
|
Yes
|
Yes
|
none
|
Environment temperature
|
20-30
|
20-30
|
20-30
|
20-30
|
Environment relative humidity
|
5-99%
|
5-99%
|
5-99%
|
5-99%
|
Environment air velocity of flow
|
0.3m/s
|
0.3m/s
|
0.3m/s
|
0.3m/s
|
RS-232 connector
|
Yes
|
Yes
|
Yes
|
None
|
Rail
|
Yes
|
Yes
|
Yes
|
None
|
Infant bed tilt adjusting
|
±10°stepless
|
±10°stepless
|
±10°stepless
|
None
|
Mattress tray max.load
|
10kg
|
10kg
|
10kg
|
10kg
|
Transfusion.pole max load
|
2kg
|
2kg
|
2kg
|
2kg
|
Cabinet Max.load
|
6kg
|
10kg
|
10kg
|
None
|
YC
Sic function,and add:infant dadjusted with stepless.
CM
Basic function,and add:side door for operation ,such as injecting to infant scalp.
SC
Basic function,and add:Dual Air Curtains.
GL
Basic function,and add:Phototherapy(blue light)unit,LED display timer,display treatment time and total time.
SGL
Basic function,and add two Phototherapy(blue light)unit,LED display timer,display treatment time and total time. |