ProductName£º KGW9000C 12.1 touch screen patient monitor
ProductIntroduce£º

 12.1" color TFT touch screen

Windows style, Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available. 
Supporting wire or wireless network.
 
Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.
 
 
Technical Specifications
 
ECG
 
Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection                     I, II, III, avR, avL, avF, V
Wavef orm                          2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 
Lead selection                     I, II, III,
Wave form                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
 
HR and Alarm Range                 Adult    15 ~ 300 bpm
                                   Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm 
Sensitivity                        > 200 (uVp-p) 
Differential Input Impedance       > 5 MΩ
 
CMRR                   Monitor > 105 dB 
                                   Operation > 105 dB 
                                   Diagnosis > 85 dB
Electrode offset potential         ±300mV 
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi. 
ECG Signal Range                   ±8 m V ( Vp-p ) 
 
Bandwidth                           Surgery    1 ~ 20 Hz
                                    Monitor     0.5 ~ 40 Hz
                                    Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                                          PNP, PNC,Alarm Available,Review Available
 
 
Respiration
 
Method                           Impedance between R-F(RA-LL)
Differential Input Impedance       > 2.5 MΩ
Measuring Impedance Range          0.3~3 Ω
Base line Impedance Range           200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                         Measuring and Alarm Range
                                    Adult 0 ~ 120 Brpm 
                                    Neo/Ped 0 ~ 150 Brpm 
                                    Resolution 1 Brpm 
                                    Accuracy ±2 Brpm
 
Apnea Alarm                        10 ~ 40 S
 
 
 
 
 
NIBP 
 
Method                            Oscillometric
Mode                              Manual, Auto, STAT                        
Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range          40 ~ 240 bpm
Alarm Type                 SYS, DIA, MEAN
 
Measuring and alarm range        Adult Mode
                                    SYS 40 ~ 270 mmHg 
                                    DIA 10 ~ 215 mmHg 
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg 
                                    DIA 10 ~ 150 mmHg 
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg 
                                    DIA 10 ~ 100 mmHg 
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg
 
Accuracy                        Maximum Mean error ±5mmHg
                                Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg 
                                 Pediatric Mode 240±3 mmHg 
                                 Neonatal Mode 147±3 mmHg
 
SpO2
Measuring Range                  0 ~ 100 % 
Alarm Range                      0 ~ 100 % 
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout      1 Sec. 
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                 Resolution       1bpm
                                 Accuracy ±3bpm
                                   
 
 
TEMP
 
Channel                          2
Measuring and Alarm Range 0 ~ 50 ¡æ
Resolution                      0.1 ¡æ
Accuracy                ±0.2 ¡æ
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.
 
 
IBP
 
Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg 
                                PA -6 ~ 120 mmHg
                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                P1 / P2-10 ~ 300 mmHg 
 
 
Press Sensor                    Sensitivity 5  uV/V/mmHg
                                Impedance 300-3000Ω
 
Resolution                      1 mmHg
Accuracy                        ±2% or 1mmHg which is greater
Actualization interval        about 1 secretary
 
 
   
 
 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
 
   
 
 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
 
 
 
 
 
 
 
 
 
 